{"id":13,"date":"2009-08-23T15:33:33","date_gmt":"2009-08-23T15:33:33","guid":{"rendered":"http:\/\/msftechnologies.com\/www.ww\/?page_id=13"},"modified":"2012-05-14T17:54:20","modified_gmt":"2012-05-14T17:54:20","slug":"our-network","status":"publish","type":"page","link":"https:\/\/msftechnologies.com\/www.ww\/our-network\/","title":{"rendered":"Our Network"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/msftechnologies.com\/www.ww\/wp-content\/uploads\/2009\/08\/escher_monkeymen-300x219.jpg\" alt=\"\" title=\"Our Network\" width=\"300\" height=\"219\" class=\"alignleft size-medium wp-image-383\" srcset=\"https:\/\/msftechnologies.com\/www.ww\/wp-content\/uploads\/2009\/08\/escher_monkeymen-300x219.jpg 300w, https:\/\/msftechnologies.com\/www.ww\/wp-content\/uploads\/2009\/08\/escher_monkeymen.jpg 432w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><strong>\u203a <\/strong>Our datacenter is located in Texas and is staffed 24\/7\/365. There are multiple OC48 SONET fiber rings that provide basic connectivity to eight access carriers. The datacenter is completely redundant, including a 2200 gallon backup diesel generator. There are over 580 smoke detectors throughout each facility, with a VESDA contaminate system.<br \/>\n<\/p>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>DLLSTX2: Stemmons Freeway, Dallas, TX<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>78,500 sq. ft. facility<\/li>\n<li>35,500 sq. ft. raised floor<\/li>\n<li>(23) HVAC units totalling 574 tons<\/li>\n<li>Very Early Smoke Detection Apparatus (VESDA)<\/li>\n<li>Pre-action dry pipe sprinkler system<\/li>\n<li>Over 500 smoke detectors in integrated system<\/li>\n<li>Northern Proximity security badge entry\/exit<\/li>\n<li>Multiple TXU electrical grids<\/li>\n<li>4800 amps of 480v input power<\/li>\n<li>3 main transfer switches<\/li>\n<li>(3) 500KVA Powerware UPS units, 90 batteries each<\/li>\n<li>Standalone PDUs at each cabinet row<\/li>\n<li>1-megawatt generator (2000 gallon tank)<\/li>\n<li>1.5-megawatt generator (2200 gallon tank)<\/li>\n<li>DataTrax monitoring for all datacenter infrastructure<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>DLLSTX4: Downtown, Dallas, TX<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>22,000 sq. ft. facility<\/li>\n<li>18,000 sq. ft. raised floor<\/li>\n<li>(12) 26-ton Data Air AC units<\/li>\n<li>Very Early Smoke Detection Apparatus (VESDA)<\/li>\n<li>Pre-action dry pipe sprinkler system<\/li>\n<li>Over 220 smoke detectors in integrated system<\/li>\n<li>Northern Proximity security badge entry\/exit<\/li>\n<li>TXU fault tolerant electrical grid<\/li>\n<li>2000 amps of 480v input power<\/li>\n<li>1 main transfer switches<\/li>\n<li>(2) 500KVA Powerware UPS units, 90 batteries each<\/li>\n<li>Standalone PDUs at each cabinet row<\/li>\n<li>1.5-megawatt generator (2200 gallon tank)<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>DLLSTX5: Infomart, Dallas, TX<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>51,000 sq. ft. facility<\/li>\n<li>35,000 sq. ft. raised floor<\/li>\n<li>(25) HVAC units totalling 775 tons<\/li>\n<li>Very Early Smoke Detection Apparatus (VESDA)<\/li>\n<li>Pre-action dry pipe sprinkler system<\/li>\n<li>Over 400 smoke detectors in integrated system<\/li>\n<li>Northern Proximity security badge entry\/exit<\/li>\n<li>Multiple TXU fault tolerant electrical grid<\/li>\n<li>4600 amps of 480v input power<\/li>\n<li>3 main transfer switches<\/li>\n<li>(6) 500KVA Powerware UPS units, 120 batteries each<\/li>\n<li>Standalone PDUs at each cabinet row<\/li>\n<li>3.5-megawatts of generating capacity<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>DLLSTX6: Stemmons Freeway, Dallas, TX<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>72,000 sq. ft. facility<\/li>\n<li>(8) HVAC units totalling 240 tons <span class=\"expansion\">(expanding to 1650 tons)<\/span><\/li>\n<li>Dual 550 ton carrier chillers <span class=\"expansion\">(adding one more)<\/span><\/li>\n<li>Very Early Smoke Detection Apparatus (VESDA)<\/li>\n<li>Pre-action dry pipe sprinkler system<\/li>\n<li>Over 500 smoke detectors in integrated system <span class=\"expansion\">(increasing to 1000)<\/span><\/li>\n<li>Northern Proximity security badge entry\/exit<\/li>\n<\/ul><\/div>\n<\/div>\n<p><strong>Network Infrastructure:<\/strong><\/p>\n<p>Sites will be accessible via a fully meshed and redundant Certified Cisco Network featuring 10 backbone providers. These providers include:<\/p>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>Backbone Carriers<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>3 Gbps Direct Fiber &#8211; Global Crossing<\/li>\n<li>3 Gbps Direct Fiber &#8211; UUNET<\/li>\n<li>5 Gbps Direct Fiber &#8211; AT&amp;T<\/li>\n<li>4 Gbps Direct Fiber &#8211; Level3<\/li>\n<li>4 Gbps Direct Fiber &#8211; AboveNet<\/li>\n<li>4 Gbps Direct Fiber &#8211; Savvis<\/li>\n<li>1 Gbps Direct Fiber &#8211; Time Warner<\/li>\n<li>4 Gbps Direct Fiber &#8211; Private Peers<\/li>\n<\/ul>\n<\/div>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>Network<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>Cisco Certified Network<\/li>\n<li>Juniper M20 Border Routers<\/li>\n<li>Cisco 6500 Series Distribution Routing Switches<\/li>\n<li>Cisco 6500 Series Aggregation Switches<\/li>\n<li>100% Uptime SLA utilizing HSRP\/BGP<\/li>\n<\/ul>\n<\/div>\n<div class=\"innerBlock\">\n<p class=\"bodyCopyHeadlineDivider\"><strong>Building Fiber<\/strong><\/p>\n<div class=\"divLeftList\">\n<ul>\n<li>OC48 SONET Ring &#8211; SBC<\/li>\n<li>OC48 SONET Ring &#8211; Time Warner<\/li>\n<li>OC48 SONET Ring &#8211; XO Communications<\/li>\n<li>OC48 SONET Ring &#8211; MCI<\/li>\n<li>OC48 SONET Ring &#8211; Looking Glass<\/li>\n<li>OC48 SONET Ring &#8211; Broadwing<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u203a Our datacenter is located in Texas and is staffed 24\/7\/365. There are multiple OC48 SONET fiber rings that provide basic connectivity to eight access carriers. The datacenter is completely redundant, including a 2200 gallon backup diesel generator. There are over 580 smoke detectors throughout each facility, with a VESDA contaminate system. DLLSTX2: Stemmons Freeway, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-no-sidebar.php","meta":{"footnotes":""},"class_list":["post-13","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/pages\/13","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/comments?post=13"}],"version-history":[{"count":7,"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/pages\/13\/revisions"}],"predecessor-version":[{"id":387,"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/pages\/13\/revisions\/387"}],"wp:attachment":[{"href":"https:\/\/msftechnologies.com\/www.ww\/wp-json\/wp\/v2\/media?parent=13"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}